Gas & Carbon Monoxide Detectors

Gas & Carbon Monoxide Detectors

 

CO&Gas detector

Voltage:DC12V or AC220V Alarm current: 《100mA
CO: Alarm density:
30ppm,alarms not activate within 120 minutes
50ppm,alarms within 60-90 minutes
100ppm,alarm with 10-40 minutes
300ppm,alarm within 3 minutes

 

Co detector

CO: Alarm density:
30ppm,alarms not activate within 120 minutes
50ppm,alarms within 60-90 minutes
100ppm,alarm with 10-40 minutes
300ppm,alarm within 3 minutes
Standby current:<25uA Alarm current:<45mA

 

High reliability sensor MCU processing adopted Malfuction auto-check indicator Sound & Flash alarm output Designed to detect gas, LPG
SMT manufacture technology, good stability
Operating voltage: AC100-250V Raged power: 3W
Alarm output: sound and flash alarm,N.O. or N.C。

 

 

1, Voltage: DC 3V (battery-powered) ;10 years battery life. 2, Standby current: <5uA
Red flashes Gas leak alarm
Green flashes activated internal sensor Green alway lights Normal working Yellow alway lights An internal fault
3,Alarm current: <40mA ;4, Humidity: ≤95% RH
5, Low battery alarm threshold: 2.5V ± 0.1V

 

 

Power Source:DC9-16V
Static Current:≤90mA;Alarm Current:≤100mA Buzzer Level:≥85dB/m
Alarm level:10%LEL (0.5%) (5000PPM)
Ambient Humidity:≤95% RH ;Warm-up time:about 180s
Alarm indicator:red LED flash
Failure indicator:yellow LED on & beeper long-buzz Alarm Mode:flashes & sound alarm/network alarm signal Output signal(optional):shut off electromagnetic

 

Natural gas/LPG detector,

AC110-240V Static current: ≤50mA
Alarm current: ≤100mA
Buzzer level: ≥80dB/m
Alarm density: 10%LEL (0.5%)(5000PPM) Alarm density Error:≤±3%LEL
Alarm mode: Flash & Sound alarm/Shut off gas valve/Network alarm signal

 

wireless gas detector

Detect gas: gas, LPG, natural gas
Power Source: AC110-220V Buzzer Level: ≥85dB/m
Alarm level: 10%LEL (0.5%) (5000PPM) Operating Temperature: -10~+50℃ Ambient Humidity: ≤95% RH
Warm-up time: about 180s
Alarm indicator: red LED flash
Failure indicator: yellow LED on & beeper long-buzz Alarm Mode: 433MHz/315MHz Optional: shut off valve

 

High reliability sensor MCU processing adopted Malfuction auto-check indicator Sound & Flash alarm output Designed to detect CO
SMT manufacture technology, good stability
Operating voltage: AC100-250V Raged power: 3W
Alarm output: sound and flash alarm
Alarm Level: CO 150PPM Electrify Time: ≤30s
Operating Temperature:-10℃ to +55℃
Operating Humidity: ≤95% RH Alarm Density Error: ±10%, Drivable accessaries: Electromagnetic valve & exhaust fan

 

Electromagnetic Valve,1/2″(DN15),Brass material

Suitable gas types: town gas Body: wrought aluminum alloy Sealing material: NBR rubber Operation temperature: -10~15
Pressure max: 50Kpa Connection: G1/2″, G3/4″ Turn on: manual
Closing modes: current impulse or manua
Driving voltage: DC9-12V Close time: <1sec
Explosion proof mark: exmb ||T4
Lead wire: 0.4m

 

 

Electromagnetic Valve,3/4″(DN20),Brass material

Suitable gas types: town gas Body: wrought aluminum alloy Sealing material: NBR rubber Operation temperature: -10~15
Pressure max: 50Kpa Connection: G1/2″, G3/4″ Turn on: manual
Closing modes: current impulse or manua
Driving voltage: DC9-12V Close time: <1sec
Explosion proof mark: exmb ||T4
Lead wire: 0.4m